NetScaler SDX

Convert a NetScaler MPX 26000-50S appliance to a NetScaler SDX 26000-50S appliance

You can convert a NetScaler MPX appliance to an NetScaler SDX appliance by upgrading the software through a new solid-state drive (SSD). NetScaler supplies a field conversion kit to migrate a NetScaler MPX appliance to an SDX appliance.

The conversion requires all eight SSDs.

Note:

Citrix recommends that you configure the lights out management (LOM) port of the appliance before starting the conversion process. For more information on the LOM port of the ADC appliance, see Lights out management port of the NetScaler SDX appliance.

To convert an MPX appliance to an SDX appliance, you must access the appliance through a console cable attached to a computer or terminal. Before connecting the console cable, configure the computer or terminal to support the following configuration:

  • VT100 terminal emulation
  • 9600 baud
  • 8 data bits
  • 1 stop bit
  • Parity and flow control set to NONE

Connect one end of the console cable to the RS232 serial port on the appliance, and the other end to the computer or terminal.

Note:

To use a cable with an RJ-45 converter, insert the optional converter into the console port and attach the cable to it.

With the cable attached, verify that the MPX appliance’s components are functioning correctly. You are then ready to begin the conversion. The conversion process modifies the BIOS, installs a Citrix Hypervisor and a Service Virtual Machine image, and copies the NetScaler VPX image to the Solid State Drive.

The conversion process also sets up a redundant array of independent disks (RAID) controller for local storage and NetScaler VPX storage. SSD slots #1 and #2 are used for local storage and SSD slots #3, #4, #5, #6, #7, and #8 are used for NetScaler VPX storage.

After the conversion process, modify the appliance’s configuration and apply a new license. You can then provision the VPX instances through the Management Service on what is now an NetScaler SDX appliance.

Verify proper operation of the MPX appliance’s components

  1. Access the console port and enter the administrator credentials.
  2. Run the following command from the command line interface of the appliance to display the serial number: show hardware. You might need the serial number to log on to the appliance after the conversion.

    Example

    > show hardware
    Platform: NSMPX-26000-50S 28*CPU+256GB+4*MLX(50)+16*F2X+2*E1K+4*4-CHIP CO 520310
    Manufactured on: 9/15/2020
    CPU: 2400MHZ
    Host Id: 1862303878
    Serial no: 83WRVD62EM
    Encoded serial no: 83WRVD62EM
    Netscaler UUID: 258f9971-f7db-11ea-b021-00e0ed9041b6
    BMC Revision: 5.03
    Done
    <!--NeedCopy-->
    

    The serial number might be helpful when you want to contact Citrix technical support.

  3. Run the following command to display the status of the active interfaces:

    show interface

    Example

    > show interface
    
    1)  Interface 0/1 (Gig Ethernet 10/100/1000 MBits) #8
    flags=0xc020 <ENABLED, UP, UP, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=0c:c4:7a:56:64:7e, uptime 120h29m33s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    Actual: media UTP, speed 1000, duplex FULL, fctl OFF, throughput 1000
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(1614945) Bytes(104805024) Errs(0) Drops(1601312) Stalls(0)
    TX: Pkts(9166) Bytes(2556380) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    
    2)  Interface 0/2 (Gig Ethernet 10/100/1000 MBits) #9
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=0c:c4:7a:56:64:7f, downtime 120h29m53s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
            throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    
    3)  Interface 25/1 (25G Ethernet, unknown device) #10
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:bc, downtime 120h29m53s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    4)  Interface 25/2 (25G Ethernet, unknown device) #11
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:bd, downtime 120h29m53s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    5)  Interface 25/3 (25G Ethernet, unknown device) #12
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:be, downtime 120h29m53s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    6)  Interface 25/4 (25G Ethernet, unknown device) #13
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:bf, downtime 120h29m53s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    7)  Interface 25/5 (25G Ethernet, unknown device) #14
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:f2, downtime 120h29m53s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    8)  Interface 25/6 (25G Ethernet, unknown device) #15
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:f3, downtime 120h29m53s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    9)  Interface 25/7 (25G Ethernet, unknown device) #16
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:f4, downtime 120h29m53s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    10) Interface 25/8 (25G Ethernet, unknown device) #17
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:f5, downtime 120h30m00s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    11) Interface 25/9 (25G Ethernet, unknown device) #2
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:b4, downtime 120h30m00s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    12) Interface 25/10 (25G Ethernet, unknown device) #3
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:b5, downtime 120h30m00s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    13) Interface 25/11 (25G Ethernet, unknown device) #0
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:b6, downtime 120h30m00s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    14) Interface 25/12 (25G Ethernet, unknown device) #1
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:b7, downtime 120h30m00s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    15) Interface 25/13 (25G Ethernet, unknown device) #6
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:ee, downtime 120h30m00s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    16) Interface 25/14 (25G Ethernet, unknown device) #7
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:ef, downtime 120h30m00s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    17) Interface 25/15 (25G Ethernet, unknown device) #4
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:f0, downtime 120h30m00s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    18) Interface 25/16 (25G Ethernet, unknown device) #5
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=00:e0:ed:90:41:f1, downtime 120h30m00s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    Rx Ring: Configured size=2048, Actual size=512, Type: Elastic
    
    19) Interface 50/1 (mce Ethernet, unknown device) #20
    flags=0xc020 <ENABLED, UP, UP, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=9216, native vlan=1, MAC=24:8a:07:a4:91:0c, uptime 99h59m54s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    Actual: media UTP, speed 50000, duplex FULL, fctl OFF, throughput 50000
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(215681) Bytes(11431096) Errs(0) Drops(215680) Stalls(0)
    TX: Pkts(131) Bytes(5516) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    
    20) Interface 50/2 (mce Ethernet, unknown device) #21
    flags=0xc020 <ENABLED, UP, UP, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=24:8a:07:a4:91:0d, uptime 100h00m22s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    Actual: media UTP, speed 50000, duplex FULL, fctl OFF, throughput 50000
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(313720) Bytes(17365302) Errs(0) Drops(312232) Stalls(0)
    TX: Pkts(114) Bytes(4788) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    
    21) Interface 50/3 (100G Ethernet) #18
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=24:8a:07:a4:91:00, downtime 120h30m07s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    
    22) Interface 50/4 (100G Ethernet) #19
    flags=0x4000 <ENABLED, DOWN, down, autoneg, HAMON, HEARTBEAT, 802.1q>
    MTU=1500, native vlan=1, MAC=24:8a:07:a4:91:01, downtime 120h30m07s
    Requested: media AUTO, speed AUTO, duplex AUTO, fctl OFF,
             throughput 0
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(0) Bytes(0) Errs(0) Drops(0) Stalls(0)
    NIC: InDisc(0) OutDisc(0) Fctls(0) Stalls(0) Hangs(0) Muted(0)
    Bandwidth thresholds are not set.
    
    23)     Interface LO/1 (Netscaler Loopback interface) #22
        flags=0x20008020 <ENABLED, UP, UP>
    MTU=9216, native vlan=1, MAC=0c:c4:7a:56:64:7e, uptime 120h30m01s
    LLDP Mode: NONE,             LR Priority: 1024
     
    RX: Pkts(611167959) Bytes(89143315781) Errs(0) Drops(0) Stalls(0)
    TX: Pkts(1207140213) Bytes(120806672260) Errs(0) Drops(0) Stalls(0)
    Bandwidth thresholds are not set.
    
    Done
    >
    <!--NeedCopy-->
    
  4. In the show interface command’s output, verify that all the interfaces are enabled and the status of every interface is shown as UP/UP.

    Notes:

    • The interface status is displayed as UP/UP only if the cables are connected to the interfaces.

    • If you do not have an SFP+ transceiver for every port, verify the interfaces in stages. After checking the first set of interfaces, unplug the SFP+ transceivers and plug them in to the next set of ports.

  5. Run the following command for each of the interfaces that are not in the UP/UP state: enable interface 50/x Where x is the new interface number.

    > enable interface 50/1
      Done
    > enable interface 50/2
      Done
    > enable interface 50/3
      Done
    > enable interface 50/4
      Done
    <!--NeedCopy-->
    
  6. Run the following command to verify that the status of the power supplies is normal:

    stat system –detail

Example

> stat system -detail

Citrix ADC Executive View

System Information:
Up since    Wed Jan 20 21:35:18 2021
Up since(Local) Wed Jan 20 21:35:18 2021
Memory usage (MB)               5802
InUse Memory (%)                2.52
Number of CPUs                    15
 
System Health Statistics (Standard):
CPU 0 Core Voltage (Volts)                  1.80
CPU 1 Core Voltage (Volts)                  1.80
Main 3.3 V Supply Voltage                   3.35
Standby 3.3 V Supply Voltage                    3.25
+5.0 V Supply Voltage                           5.03
+12.0 V Supply Voltage                         12.13
Battery Voltage (Volts)                         2.98
Intel CPU Vtt Power(Volts)                      0.00
5V Standby Voltage(Volts)                   4.97
Voltage Sensor2(Volts)                      0.00
CPU Fan 0 Speed (RPM)                       3100
CPU Fan 1 Speed (RPM)                       3100
System Fan Speed (RPM)                      3100
System Fan 1 Speed (RPM)                    3100
System Fan 2 Speed (RPM)                    3100
CPU 0 Temperature (Celsius)                       47
CPU 1 Temperature (Celsius)                       51
Internal Temperature (Celsius)                    35
Power supply 1 status                         NORMAL
Power supply 2 status                         NORMAL
Power supply 3 status              NOT SUPPORTED
Power supply 4 status              NOT SUPPORTED
 
System Disk Statistics:
/flash Size (MB)                               23801
/flash Used (MB)                                 787
/flash Available (MB)                          21110
/flash Used (%)                                    3
/var Size (MB)                                341167
/var Used (MB)                                112391
/var Available (MB)                           201482
/var Used (%)                                     35
 
System Health Statistics(Auxiliary):
Voltage 0 (Volts)                           1.20
Voltage 1 (Volts)                           1.20
Voltage 2 (Volts)                           1.21
Voltage 3 (Volts)                           1.20
Voltage 4 (Volts)                           1.54
Voltage 5 (Volts)                           0.00
Voltage 6 (Volts)                           0.00
Voltage 7 (Volts)                           0.00
Fan 0 Speed (RPM)                           3200
Fan 1 Speed (RPM)                              0
Fan 2 Speed (RPM)                              0
Fan 3 Speed (RPM)                              0
Temperature 0 (Celsius)                       27
Temperature 1 (Celsius)                       38
Temperature 2 (Celsius)                        0
Temperature 3 (Celsius)                        0
 Done
>
<!--NeedCopy-->
  1. Run the following command to generate a tar of system configuration data and statistics:

    show techsupport

    Example

    > show techsupport
    
    showtechsupport data collector tool - $Revision$!
    NetScaler version 13.0
    The NS IP of this box is 10.217.206.43
    This is not HA configuration
    Copying selected configuration files ....
    Running shell commands ....
    Running CLI show commands ....
    Collecting ns running configuration....
    Collecting running gslb configuration....
    Running CLI stat commands ....
    Running vtysh commands ....
    Copying newnslog files ....
    Copying core files from /var/core ....
    Copying core files from /var/crash ....
    Copying GSLB location database files ....
    Copying GSLB auto sync log files ....
    Copying Safenet Gateway log files ....
    Copying messages, ns.log, dmesg and other log files ....
    Creating archive ....
    /var/tmp/support/support.tgz  ---- points to ---> /var/tmp/support/collector_P_10.217.206.43_5Dec2020_05_32.tar.gz
    
    showtechsupport script took 1 minute(s) and 17 second(s) to execute.
    Done
    <!--NeedCopy-->
    

    Note

    The output of the command is available in the /var/tmp/support/collector_<IP_address>_P_<date>.tar.gz file. Copy this file to another computer for future reference. The output of the command might be helpful when you want to contact Citrix technical support.

  2. At the command line interface, switch to the shell prompt. Type: shell

    Example

    > shell
    Copyright (c) 1992-2013 The FreeBSD Project.
    Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994
        The Regents of the University of California. All rights reserved.
    
    root@ns#
    <!--NeedCopy-->
    
  3. Run the following command to verify the memory on your appliance:

    root@ns# grep "memory" /var/nslog/dmesg.boot

    Example

    root@ns# grep "memory" /var/nslog/dmesg.boot
    real memory  = 274877906944 (262144 MB)
    avail memory = 264024535040 (251793 MB)
    root@ns#
    <!--NeedCopy-->
    
  4. Run the following command to verify the number of CPU cores depending upon your appliance:

    root@ns# grep "cpu" /var/nslog/dmesg.boot

    Example

    root@ns# grep "cpu" /var/nslog/dmesg.boot
    cpu0 (BSP): APIC ID:  0
    cpu1 (AP): APIC ID:  2
    cpu2 (AP): APIC ID:  4
    cpu3 (AP): APIC ID:  6
    cpu4 (AP): APIC ID:  8
    cpu5 (AP): APIC ID: 10
    cpu6 (AP): APIC ID: 12
    cpu7 (AP): APIC ID: 16
    cpu8 (AP): APIC ID: 18
    cpu9 (AP): APIC ID: 20
    cpu10 (AP): APIC ID: 22
    cpu11 (AP): APIC ID: 24
    cpu12 (AP): APIC ID: 26
    cpu13 (AP): APIC ID: 28
    cpu14 (AP): APIC ID: 32
    cpu15 (AP): APIC ID: 34
    cpu16 (AP): APIC ID: 36
    cpu17 (AP): APIC ID: 38
    cpu18 (AP): APIC ID: 40
    cpu19 (AP): APIC ID: 42
    cpu20 (AP): APIC ID: 44
    cpu21 (AP): APIC ID: 48
    cpu22 (AP): APIC ID: 50
    cpu23 (AP): APIC ID: 52
    cpu24 (AP): APIC ID: 54
    cpu25 (AP): APIC ID: 56
    cpu26 (AP): APIC ID: 58
    cpu27 (AP): APIC ID: 60
    cpu0: <ACPI CPU> on acpi0
    cpu1: <ACPI CPU> on acpi0
    cpu2: <ACPI CPU> on acpi0
    cpu3: <ACPI CPU> on acpi0
    cpu4: <ACPI CPU> on acpi0
    cpu5: <ACPI CPU> on acpi0
    cpu6: <ACPI CPU> on acpi0
    cpu7: <ACPI CPU> on acpi0
    cpu8: <ACPI CPU> on acpi0
    cpu9: <ACPI CPU> on acpi0
    cpu10: <ACPI CPU> on acpi0
    cpu11: <ACPI CPU> on acpi0
    cpu12: <ACPI CPU> on acpi0
    cpu13: <ACPI CPU> on acpi0
    cpu14: <ACPI CPU> on acpi0
    cpu15: <ACPI CPU> on acpi0
    cpu16: <ACPI CPU> on acpi0
    cpu17: <ACPI CPU> on acpi0
    cpu18: <ACPI CPU> on acpi0
    cpu19: <ACPI CPU> on acpi0
    cpu20: <ACPI CPU> on acpi0
    cpu21: <ACPI CPU> on acpi0
    cpu22: <ACPI CPU> on acpi0
    cpu23: <ACPI CPU> on acpi0
    cpu24: <ACPI CPU> on acpi0
    cpu25: <ACPI CPU> on acpi0
    cpu26: <ACPI CPU> on acpi0
    cpu27: <ACPI CPU> on acpi0
    est0: <Enhanced SpeedStep Frequency Control> on cpu0
    p4tcc0: <CPU Frequency Thermal Control> on cpu0
    est1: <Enhanced SpeedStep Frequency Control> on cpu1
    p4tcc1: <CPU Frequency Thermal Control> on cpu1
    est2: <Enhanced SpeedStep Frequency Control> on cpu2
    p4tcc2: <CPU Frequency Thermal Control> on cpu2
    est3: <Enhanced SpeedStep Frequency Control> on cpu3
    p4tcc3: <CPU Frequency Thermal Control> on cpu3
    est4: <Enhanced SpeedStep Frequency Control> on cpu4
    p4tcc4: <CPU Frequency Thermal Control> on cpu4
    est5: <Enhanced SpeedStep Frequency Control> on cpu5
    p4tcc5: <CPU Frequency Thermal Control> on cpu5
    est6: <Enhanced SpeedStep Frequency Control> on cpu6
    p4tcc6: <CPU Frequency Thermal Control> on cpu6
    est7: <Enhanced SpeedStep Frequency Control> on cpu7
    p4tcc7: <CPU Frequency Thermal Control> on cpu7
    est8: <Enhanced SpeedStep Frequency Control> on cpu8
    p4tcc8: <CPU Frequency Thermal Control> on cpu8
    est9: <Enhanced SpeedStep Frequency Control> on cpu9
    p4tcc9: <CPU Frequency Thermal Control> on cpu9
    est10: <Enhanced SpeedStep Frequency Control> on cpu10
    p4tcc10: <CPU Frequency Thermal Control> on cpu10
    est11: <Enhanced SpeedStep Frequency Control> on cpu11
    p4tcc11: <CPU Frequency Thermal Control> on cpu11
    est12: <Enhanced SpeedStep Frequency Control> on cpu12
    p4tcc12: <CPU Frequency Thermal Control> on cpu12
    est13: <Enhanced SpeedStep Frequency Control> on cpu13
    p4tcc13: <CPU Frequency Thermal Control> on cpu13
    est14: <Enhanced SpeedStep Frequency Control> on cpu14
    p4tcc14: <CPU Frequency Thermal Control> on cpu14
    est15: <Enhanced SpeedStep Frequency Control> on cpu15
    p4tcc15: <CPU Frequency Thermal Control> on cpu15
    est16: <Enhanced SpeedStep Frequency Control> on cpu16
    p4tcc16: <CPU Frequency Thermal Control> on cpu16
    est17: <Enhanced SpeedStep Frequency Control> on cpu17
    p4tcc17: <CPU Frequency Thermal Control> on cpu17
    est18: <Enhanced SpeedStep Frequency Control> on cpu18
    p4tcc18: <CPU Frequency Thermal Control> on cpu18
    est19: <Enhanced SpeedStep Frequency Control> on cpu19
    p4tcc19: <CPU Frequency Thermal Control> on cpu19
    est20: <Enhanced SpeedStep Frequency Control> on cpu20
    p4tcc20: <CPU Frequency Thermal Control> on cpu20
    est21: <Enhanced SpeedStep Frequency Control> on cpu21
    p4tcc21: <CPU Frequency Thermal Control> on cpu21
    est22: <Enhanced SpeedStep Frequency Control> on cpu22
    p4tcc22: <CPU Frequency Thermal Control> on cpu22
    est23: <Enhanced SpeedStep Frequency Control> on cpu23
    p4tcc23: <CPU Frequency Thermal Control> on cpu23
    est24: <Enhanced SpeedStep Frequency Control> on cpu24
    p4tcc24: <CPU Frequency Thermal Control> on cpu24
    est25: <Enhanced SpeedStep Frequency Control> on cpu25
    p4tcc25: <CPU Frequency Thermal Control> on cpu25
    est26: <Enhanced SpeedStep Frequency Control> on cpu26
    p4tcc26: <CPU Frequency Thermal Control> on cpu26
    est27: <Enhanced SpeedStep Frequency Control> on cpu27
    p4tcc27: <CPU Frequency Thermal Control> on cpu27
    root@ns#
    <!--NeedCopy-->
    
  5. Run the following command to verify that the /var drive is mounted as /dev/ ar0s1a: root@ns# df –h

    Example

    root@ns# df -h
    Filesystem     Size    Used   Avail Capacity  Mounted on
    /dev/md0       422M    404M    9.1M    98%    /
    devfs          1.0k    1.0k      0B   100%    /dev
    procfs         4.0k    4.0k      0B   100%    /proc
    /dev/ar0s1a     23G    6.9G     14G    32%    /flash
    /dev/ar0s1e    333G     32G    274G    10%    /var
    root@ns#
    <!--NeedCopy-->
    
  6. Type the following command to run the ns_hw_err.bash script, which checks for latent hardware errors:

    root@ns# ns_hw_err.bash

    Example

    root@ns# ns_hw_err.bash
    NetScaler NS13.0: Build 73.17.nc, Date: Nov 11 2020, 07:56:08   (64-bit)
    platform: serial 83WRVD62EM
    platform: sysid 520310 - NSMPX-26000-50S 28*CPU+256GB+4*MLX(50)+16*F2X+2*E1K+4*4-CHIP COL 8955
    HDD MODEL: ar0: 434992MB <Intel MatrixRAID RAID1> status: READY
        
    Generating the list of newnslog files to be processed...
    Generating the events from newnslog files...
    Checking for HDD errors...
    Checking for HDD SMART errors...
    Checking for Flash errors...
    Checking for Mega Raid Controller errors...
    Checking for SSL errors...
    Checking for BIOS errors...
    Checking for SMB errors...
    Checking for MotherBoard errors...
    Checking for CMOS errors...
            License year: 2021: OK
    Checking for SFP/NIC errors...
        
    Checking for Firmware errors...
    Checking for License errors...
    Checking for Undetected CPUs...
    Checking for DIMM flaps...
    Checking for Memory Channel errors...
    Checking for LOM errors...
    Checking the Power Supply Errors...
    Checking for Hardware Clock errors...
    Script Done.
    root@ns#
    <!--NeedCopy-->
    

    Important: Physically disconnect all ports, except the LOM port, including the management port from the network.

  7. At the shell prompt, switch to the ADC command line. Type: exit

    Example

    root@ns# exit
    logout
    Done
    <!--NeedCopy-->
    
  8. Run the following command to shut down the appliance. You are asked if you want to completely stop the ADC. Type: shutdown -p now

    Example

    > shutdown -p now
    Are you sure you want to completely stop NetScaler (Y/N)? [N]:y
    Done
    > Dec  5 06:09:11 <auth.notice> ns shutdown: power-down by root:
    Dec  5 06:09:13 <auth.emerg> ns init: Rebooting via init mechanism
    Dec  5 06:09:13 <syslog.err> ns syslogd: exiting on signal 15
    Dec  5 06:09:13 aslearn[1662]: before pthread_join(), task name: Aslearn_Packet_Loop_Task
    Dec  5 06:09:15 aslearn[1662]: Exiting function ns_do_logging
    Dec  5 06:09:15 aslearn[1662]: before pthread_join(), task name: Aslearn_WAL_Cleanup_Task
    Dec  5 06:09:15 aslearn[1662]: before pthread_join(), task name: Aslearn_HA_Primary_Task
    Dec  5 06:09:15 aslearn[1662]: 1662 exiting gracefully
    Dec  5 06:09:18 [1672]: nsnet_tcpipconnect: connect() failed; returned -1 errno=61
    qat0: qat_dev0 stopped 12 acceleration engines
    pci4: Resetting device
    qat1: qat_dev1 stopped 12 acceleration engines
    pci6: Resetting device
    qat2: qat_dev2 stopped 12 acceleration engines
    pci132: Resetting device
    qat3: qat_dev3 stopped 12 acceleration engines
    pci134: Resetting device
    Dec  5 06:09:33 init: some processes would not die; ps axl advised
    reboot initiated by init with parent kernel
    Waiting (max 60 seconds) for system process `vnlru' to stop...done
    Waiting (max 60 seconds) for system process `bufdaemon' to stop...done
    Waiting (max 60 seconds) for system process `syncer' to stop...
    Syncing disks, vnodes remaining...0 0 0 done
    All buffers synced.
    Uptime: 1h53m18s
    ixl_shutdown: lldp start 0
    ixl_shutdown: lldp start 0
    ixl_shutdown: lldp start 0
    ixl_shutdown: lldp start 0
    usbus0: Controller shutdown
    uhub0: at usbus0, port 1, addr 1 (disconnected)
    usbus0: Controller shutdown complete
    usbus1: Controller shutdown
    uhub1: at usbus1, port 1, addr 1 (disconnected)
    ugen1.2: <vendor 0x8087> at usbus1 (disconnected)
    uhub3: at uhub1, port 1, addr 2 (disconnected)
    ugen1.3: <FTDI> at usbus1 (disconnected)
    uftdi0: at uhub3, port 1, addr 3 (disconnected)
    ugen1.4: <vendor 0x1005> at usbus1 (disconnected)
    umass0: at uhub3, port 3, addr 4 (disconnected)
    (da0:umass-sim0:0:0:0): lost device - 0 outstanding, 0 refs
    (da0:umass-sim0:0:0:0): removing device entry
    usbus1: Controller shutdown complete
    usbus2: Controller shutdown
    uhub2: at usbus2, port 1, addr 1 (disconnected)
     ugen2.2: <vendor 0x8087> at usbus2 (disconnected)
    uhub4: at uhub2, port 1, addr 2 (disconnected)
    ugen2.3: <vendor 0x0557> at usbus2 (disconnected)
    uhub5: at uhub4, port 7, addr 3 (disconnected)
    ugen2.4: <vendor 0x0557> at usbus2 (disconnected)
    ukbd0: at uhub5, port 1, addr 4 (disconnected)
    ums0: at uhub5, port 1, addr 4 (disconnected)
    usbus2: Controller shutdown complete
    ixl_shutdown: lldp start 0
    ixl_shutdown: lldp start 0
    ixl_shutdown: lldp start 0
    ixl_shutdown: lldp start 0
    acpi0: Powering system off
    <!--NeedCopy-->
    

Upgrade the appliance

To upgrade the appliance, follow these steps:

  1. Power off the ADC appliance.
  2. Locate the two solid-state drives (SSDs) on the back of the appliance in slot #1 and slot #2, as shown in the following figure:

    Back panel image

  3. Verify that the replacement solid-state drives (SSDs) are the ones required for your ADC model. The conversion requires a minimum of four SSDs. The NetScaler label is on the top of one of the SSDs. The SSD is pre-populated with a new version of the BIOS and a recent build of the required NetScaler SDX Management Service. This SSD must be installed in slot # 1.

  4. Remove the SSDs by pushing the safety latch of the drive cover down while pulling the drive handle.

  5. On the new Citrix certified SSD drive, open the drive handle completely to the left. Then insert the new drive into the slot #1 as far as possible.

  6. To seat the drive, close the handle flush with the rear side of the appliance so that the drive locks securely into the slot.

    Important: The orientation of the SSD is important. When you insert the drive, make sure that the NetScaler product label is at the side, similar to the already inserted SSDs.

  7. Insert a second Citrix certified SSD, which matches the capacity of the SSD in slot #1, in slot # 2.

    Important

    Mixing and matching of old and new SSDs is not supported. SSDs in slot #1 and slot #2, which constitute the first RAID pair (local storage), must be of the same size and type. Similarly, SSDs in slot #3 and slot #4, which constitute the second RAID pair (VPX storage), must be of the same size and type. Use only drives that are part of the provided conversion kit.

  8. Insert the 960 GB blank SSD drives in slots 3, 4, 5, 6, 7, and 8.

  9. Disconnect all the network cables from the data ports and the management ports.

  10. Start the ADC appliance. For instructions, see Switch on the appliance.

    The conversion process can take up to 90 minutes, during which you must not power cycle the appliance. The entire conversion process might not be visible on the console and might appear to be unresponsive.

    The conversion process updates the BIOS, installs the Citrix Hypervisor, and the Management Service Operating system.

  11. Keep the console cable attached during the conversion process. Allow the process to complete, at which point the SDX login prompt appears.

  12. During the conversion process the LOM port connection might be lost as it resets the IP address to the default value of 192.168.1.3.

  13. The default credentials for the Citrix Hypervisor are changed to root/nsroot after the appliance is converted from an MPX to SDX. If this password does not work, try typing nsroot/the serial number of the appliance. The serial number bar code is available at the back of the appliance, and is also available in the output of the show hardware command.

    Note:

    The serial number of the appliance remains the same.

  14. To make sure that the conversion is successful, verify that the FVT result indicates success. Run the following command: tail /var/log/fvt/fvt.log

Reconfigure the converted appliance

After the conversion process, the appliance no longer has its previous working configuration. Therefore, you can access the appliance through a web browser only by using the default IP address: 192.168.100.1/16. Configure a computer on network 192.168.0.0 and connect it directly to the appliance’s management port (0/1) with a cross-over Ethernet cable. Alternately, access the NetScaler SDX appliance through a network hub by using a straight-through Ethernet cable. Use the default credentials to log on, and then do the following:

  1. Select the Dashboard tab.
  2. Verify that the System Resource section displays the accurate number of CPU cores, SSL cores, and the total memory for your NetScaler SDX appliance.
  3. Navigate to Configuration > System to modify the network information of the Management Service.
  4. In the Modify Network Configuration dialog box, specify the following details:
    • Interface: Management interface that connects the appliance to a management workstation or network. Possible values: 0/1, 0/2. Default: 0/1.
    • Gateway: IP address of the router that forwards traffic out of the appliance’s subnet.
    • Select the IPv4 checkbox if you want to use the IPv4 address for the Management Service and enter the details for the following parameters:
      • Appliance Management IP: The IPv4 address that is used to access the Management Service by using a web browser.
      • Netmask: The subnet mask in which the SDX appliance is located.
    • DNS: IPv4 address of the primary DNS server. IPv6 addresses are not supported for the primary DNS server.
    • Select the IPv6 checkbox if you want to use the IPv6 address for the Management Service and enter the details for the following parameters:
      • Management Service IP Address: The IPv6 address that is used to access the Management Service by using a Web browser.
      • Gateway IPv6 Address: The IPv4 address of the router that forwards traffic out of the appliance’s subnet.
    • Select Additional DNS to add DNS server IP addresses as an extra DNS server apart from the primary DNS server. The IP addresses can be either IPv4 or IPv6. Network configuration
  5. Click OK. Connection to the Management Service is lost as the network information was changed.

  6. Connect the NetScaler SDX appliance’s management port 0/1 to a switch to access it through the network. Browse to the IP address used earlier and log in with the default credentials.

  7. Apply the new licenses. For instructions, see SDX Licensing Overview.

  8. Navigate to Configuration > System and, in the System Administration group, click Reboot Appliance. Click Yes to confirm. You are now ready to provision the VPX instances on the NetScaler SDX appliance. For instructions, see Provisioning NetScaler instances.
Convert a NetScaler MPX 26000-50S appliance to a NetScaler SDX 26000-50S appliance