Troubleshooting high availability issues
The most common high availability issues involve the high availability feature not working at all, or working only intermittently. Following are common high availability issues, and probable causes and resolutions.
-
Issue The inability of the NetScaler appliances to pair the NetScaler appliances in a high availability setup.
-
CauseNetwork connectivityResolutionVerify that both the appliances are connected to the switch and the interfaces are enabled.
-
CauseMismatch in the Password for the default Administrator accountResolutionVerify that the password on both the appliances is the same.
-
CauseIP conflictResolutionVerify that both the appliances have unique NetScaler IP (NSIP) address. The appliances should not have the same NSIP address.
-
CauseNode ID mismatchResolutionVerify that the Node ID Configuration on both the appliances is unique. The appliances should not have the same Node ID configuration. Additionally, you must assign value for a Node ID between 1 and 64.
-
CauseMismatch in the password of the RPC nodeResolutionVerify that both the nodes have the same RPC node password.
-
CauseAn administrator has disabled the remote nodeResolutionEnable the remote node.
-
CauseThe Firewall application has blocked the heartbeat packetsResolution
-
Verify that the UDP port 3003 is allowed.
-
Issue Both the appliances claim to be the primary appliance.
-
CauseMissing heartbeat packets between the appliancesResolutionVerify that the UDP port 3003 is not blocked for communication between the appliances.
-
-
Issue The NetScaler appliance is not able to synchronize the configuration.
-
CauseA Firewall application is blocking the required port.ResolutionVerify that the UDP port 3010 (or UDP port 3008 with secure synchronization) is not blocked for communication between the appliances.
-
CauseAn administrator has disabled synchronization.ResolutionEnable synchronization on the appliance that has the issue.
-
CauseDifferent NetScaler releases or builds are installed on appliances.ResolutionUpgrade the appliances to the same NetScaler release or build.
-
-
Issue Command propagation fails between the appliances.
-
CauseA Firewall application is blocking the port.ResolutionVerify that the UDP port 3011 (or UDP port 3009 with secure propagation) is not blocked for communication between the appliances.
-
CauseAn administrator has disabled command propagation.ResolutionEnable command propagation on the appliance that has the issue.
-
CauseDifferent NetScaler releases or builds are installed on appliances.ResolutionUpgrade the appliances to the same NetScaler release or build.
-
-
Issue The NetScaler appliances in the high availability pair are unable to run the force failover process.
-
CauseThe Secondary node is disabled.ResolutionEnable the secondary node.
-
CauseThe Secondary node is configured to stay secondary.ResolutionSet the secondary high availability status of the secondary node to Enable from Stay Secondary.
-
-
Issue The secondary appliance does not receive any traffic after the failover process.
-
CauseThe upstream router does not understand GARP messages of NetScaler appliance.ResolutionConfigure virtual MAC address on the secondary appliance.
-