Getting Started with Citrix ADC
-
Deploy a Citrix ADC VPX instance
-
Install a Citrix ADC VPX instance on Microsoft Hyper-V servers
-
Install a Citrix ADC VPX instance on Linux-KVM platform
-
Prerequisites for Installing Citrix ADC VPX Virtual Appliances on Linux-KVM Platform
-
Provisioning the Citrix ADC Virtual Appliance by using OpenStack
-
Provisioning the Citrix ADC Virtual Appliance by using the Virtual Machine Manager
-
Configuring Citrix ADC Virtual Appliances to Use SR-IOV Network Interface
-
Configuring Citrix ADC Virtual Appliances to use PCI Passthrough Network Interface
-
Provisioning the Citrix ADC Virtual Appliance by using the virsh Program
-
Provisioning the Citrix ADC Virtual Appliance with SR-IOV, on OpenStack
-
Configuring a Citrix ADC VPX Instance on KVM to Use OVS DPDK-Based Host Interfaces
-
-
Deploy a Citrix ADC VPX instance on Microsoft Azure
-
Network architecture for Citrix ADC VPX instances on Microsoft Azure
-
Configure multiple IP addresses for a Citrix ADC VPX standalone instance
-
Configure a high-availability setup with multiple IP addresses and NICs
-
Configure a high-availability setup with multiple IP addresses and NICs by using PowerShell commands
-
Configure HA-INC nodes by using the Citrix high availability template with Azure ILB
-
Configure address pools (IIP) for a Citrix Gateway appliance
-
-
Upgrade and downgrade a Citrix ADC appliance
-
Solutions for Telecom Service Providers
-
Load Balance Control-Plane Traffic that is based on Diameter, SIP, and SMPP Protocols
-
Provide Subscriber Load Distribution Using GSLB Across Core-Networks of a Telecom Service Provider
-
Authentication, authorization, and auditing application traffic
-
Configuring authentication, authorization, and auditing policies
-
Configuring Authentication, authorization, and auditing with commonly used protocols
-
Use an on-premises Citrix Gateway as the identity provider for Citrix Cloud
-
Troubleshoot authentication issues in Citrix ADC and Citrix Gateway with aaad.debug module
-
-
-
-
-
-
Persistence and persistent connections
-
Advanced load balancing settings
-
Gradually stepping up the load on a new service with virtual server–level slow start
-
Protect applications on protected servers against traffic surges
-
Retrieve location details from user IP address using geolocation database
-
Use source IP address of the client when connecting to the server
-
Use client source IP address for backend communication in a v4-v6 load balancing configuration
-
Set a limit on number of requests per connection to the server
-
Configure automatic state transition based on percentage health of bound services
-
-
Use case 2: Configure rule based persistence based on a name-value pair in a TCP byte stream
-
Use case 3: Configure load balancing in direct server return mode
-
Use case 6: Configure load balancing in DSR mode for IPv6 networks by using the TOS field
-
Use case 7: Configure load balancing in DSR mode by using IP Over IP
-
Use case 10: Load balancing of intrusion detection system servers
-
Use case 11: Isolating network traffic using listen policies
-
Use case 12: Configure Citrix Virtual Desktops for load balancing
-
Use case 13: Configure Citrix Virtual Apps for load balancing
-
Use case 14: ShareFile wizard for load balancing Citrix ShareFile
-
-
-
-
-
Authentication and authorization
-
-
Configuring a CloudBridge Connector Tunnel between two Datacenters
-
Configuring CloudBridge Connector between Datacenter and AWS Cloud
-
Configuring a CloudBridge Connector Tunnel Between a Datacenter and Azure Cloud
-
Configuring CloudBridge Connector Tunnel between Datacenter and SoftLayer Enterprise Cloud
-
Configuring a CloudBridge Connector Tunnel Between a Citrix ADC Appliance and Cisco IOS Device
-
CloudBridge Connector Tunnel Diagnostics and Troubleshooting
This content has been machine translated dynamically.
Dieser Inhalt ist eine maschinelle Übersetzung, die dynamisch erstellt wurde. (Haftungsausschluss)
Cet article a été traduit automatiquement de manière dynamique. (Clause de non responsabilité)
Este artículo lo ha traducido una máquina de forma dinámica. (Aviso legal)
此内容已经过机器动态翻译。 放弃
このコンテンツは動的に機械翻訳されています。免責事項
이 콘텐츠는 동적으로 기계 번역되었습니다. 책임 부인
Este texto foi traduzido automaticamente. (Aviso legal)
Questo contenuto è stato tradotto dinamicamente con traduzione automatica.(Esclusione di responsabilità))
This article has been machine translated.
Dieser Artikel wurde maschinell übersetzt. (Haftungsausschluss)
Ce article a été traduit automatiquement. (Clause de non responsabilité)
Este artículo ha sido traducido automáticamente. (Aviso legal)
この記事は機械翻訳されています.免責事項
이 기사는 기계 번역되었습니다.책임 부인
Este artigo foi traduzido automaticamente.(Aviso legal)
这篇文章已经过机器翻译.放弃
Questo articolo è stato tradotto automaticamente.(Esclusione di responsabilità))
Translation failed!
Configure a Citrix ADC VPX instance on KVM to use OVS DPDK-based host interfaces
You can configure a Citrix ADC VPX instance running on KVM (Fedora and RHOS) to use Open vSwitch (OVS) with Data Plane Development Kit (DPDK) for better network performance. This document describes how to configure the Citrix ADC VPX instance to operate on the vhost-user ports exposed by OVS-DPDK on KVM host.
OVS is a multilayer virtual switch licensed under the open-source Apache 2.0 license. DPDK is a set of libraries and drivers for fast packet processing.
The following Fedora, RHOS, OVS, and DPDK versions are qualified for configuring a Citrix ADC VPX instance:
Fedora | RHOS |
---|---|
Fedora 25 | RHOS 7.4 |
OVS 2.7.0 | OVS 2.6.1 |
DPDK 16.11.12 | DPDK 16.11.12 |
Prerequisites
Before you install DPDK, make sure the host has 1 GB hugepages.
For more information, see this DPDK system requirements documentation. Here is the summary of the steps required to configuring a Citrix ADC VPX Instance on KVM to use OVS DPDK-based host interfaces:
- Install DPDK.
- Build and Install OVS.
- Create an OVS bridge.
- Attach a physical interface to the OVS bridge.
- Attach vhost-user ports to the OVS data path.
- Provision a KVM-VPX with OVS-DPDK based vhost-user ports.
Install DPDK
To install DPDK, follow the instruction given at this Open vSwitch with DPDK document .
Build and install OVS
Download OVS from the OVS download page. Next, build and install OVS by using a DPDK datapath. Follow the instructions given in the Installing Open vSwitch document.
For more detailed information, DPDK Getting Started Guide for Linux.
Create an OVS bridge
Depending on your need, type the Fedora or RHOS command to create an OVS bridge:
Fedora command:
> $OVS_DIR/utilities/ovs-vsctl add-br ovs-br0 -- set bridge ovs-br0 datapath_type=netdev
<!--NeedCopy-->
RHOS command:
ovs-vsctl add-br ovs-br0 -- set bridge ovs-br0 datapath_type=netdev
<!--NeedCopy-->
Attach physical interface to the OVS bridge
Bind the ports to DPDK and then attach them to the OVS bridge by typing the following Fedora or RHOS commands:
Fedora command:
> $OVS_DIR/utilities/ovs-vsctl add-port ovs-br0 dpdk0 -- set Interface dpdk0 type=dpdk options:dpdk-devargs=0000:03:00.0
> $OVS_DIR/utilities/ovs-vsctl add-port ovs-br0 dpdk1 -- set Interface dpdk1 type=dpdk options:dpdk-devargs=0000:03:00.1
<!--NeedCopy-->
RHOS command:
ovs-vsctl add-port ovs-br0 dpdk0 -- set Interface dpdk0 type=dpdk options:dpdk-devargs=0000:03:00.0
ovs-vsctl add-port ovs-br0 dpdk1 -- set Interface dpdk1 type=dpdk options:dpdk-devargs=0000:03:00.1
<!--NeedCopy-->
The dpdk-devargs shown as part of options specifies the PCI BDF of the respective physical NIC.
Attach vhost-user ports to the OVS data path
Type the following Fedora or RHOS commands to attach vhost-user ports to the OVS data path:
Fedora command:
> $OVS_DIR/utilities/ovs-vsctl add-port ovs-br0 vhost-user1 -- set Interface vhost-user1 type=dpdkvhostuser -- set Interface vhost-user1 mtu_request=9000
> $OVS_DIR/utilities/ovs-vsctl add-port ovs-br0 vhost-user2 -- set Interface vhost-user2 type=dpdkvhostuser -- set Interface vhost-user2 mtu_request=9000
chmod g+w /usr/local/var/run/openvswitch/vhost*
<!--NeedCopy-->
RHOS command:
ovs-vsctl add-port ovs-br0 vhost-user1 -- set Interface vhost-user1 type=dpdkvhostuser -- set Interface vhost-user1 mtu_request=9000
ovs-vsctl add-port ovs-br0 vhost-user2 -- set Interface vhost-user2 type=dpdkvhostuser -- set Interface vhost-user2 mtu_request=9000
chmod g+w /var/run/openvswitch/vhost*
<!--NeedCopy-->
Provision a KVM-VPX with OVS-DPDK-based vhost-user ports
You can provision a VPX instance on Fedora KVM with OVS-DPDK-based vhost-user ports only from CLI by using the following QEMU commands: Fedora command:
qemu-system-x86_64 -name KVM-VPX -cpu host -enable-kvm -m 4096M \
-object memory-backend-file,id=mem,size=4096M,mem-path=/dev/hugepages,share=on -numa node,memdev=mem \
-mem-prealloc -smp sockets=1,cores=2 -drive file=<absolute-path-to-disc-image-file>,if=none,id=drive-ide0-0-0,format=<disc-image-format> \
-device ide-drive,bus=ide.0,unit=0,drive=drive-ide0-0-0,id=ide0-0-0,bootindex=1 \
-netdev type=tap,id=hostnet0,script=no,downscript=no,vhost=on \
-device virtio-net-pci,netdev=hostnet0,id=net0,mac=52:54:00:3c:d1:ae,bus=pci.0,addr=0x3 \
-chardev socket,id=char0,path=</usr/local/var/run/openvswitch/vhost-user1> \
-netdev type=vhost-user,id=mynet1,chardev=char0,vhostforce -device virtio-net-pci,mac=00:00:00:00:00:01,netdev=mynet1,mrg_rxbuf=on \
-chardev socket,id=char1,path=</usr/local/var/run/openvswitch/vhost-user2> \
-netdev type=vhost-user,id=mynet2,chardev=char1,vhostforce -device virtio-net
pci,mac=00:00:00:00:00:02,netdev=mynet2,mrg_rxbuf=on \
--nographic
<!--NeedCopy-->
For RHOS, use the following sample XML file to provision the Citrix ADC VPX instance, by using virsh.
<domain type=’kvm’>
<name>dpdk-vpx1</name>
<uuid>aedb844b-f6bc-48e6-a4c6-36577f2d68d6</uuid>
<memory unit=’KiB’>16777216</memory>
<currentMemory unit=’KiB’>16777216</currentMemory>
<memoryBacking>
<hugepages>
<page size=’1048576’ unit=’KiB’/>
</hugepages>
</memoryBacking>
<vcpu placement=’static’>6</vcpu>
<cputune>
<shares>4096</shares>
<vcpupin vcpu=’0’ cpuset=’0’/>
<vcpupin vcpu=’1’ cpuset=’2’/>
<vcpupin vcpu=’2’ cpuset=’4’/>
<vcpupin vcpu=’3’ cpuset=’6’/>
<emulatorpin cpuset=’0,2,4,6’/>
</cputune>
<numatune>
<memory mode=’strict’ nodeset=’0’/>
</numatune>
<resource>
<partition>/machine</partition>
</resource>
<os>
<type arch=’x86_64’ machine=’pc-i440fx-rhel7.0.0’>hvm</type>
<boot dev=’hd’/>
</os>
<features>
<acpi/>
<apic/>
</features>
<cpu mode=’custom’ match=’minimum’ check=’full’>
<model fallback=’allow’>Haswell-noTSX</model>
<vendor>Intel</vendor>
<topology sockets=’1’ cores=’6’ threads=’1’/>
<feature policy=’require’ name=’ss’/>
<feature policy=’require’ name=’pcid’/>
<feature policy=’require’ name=’hypervisor’/>
<feature policy=’require’ name=’arat’/>
<domain type=’kvm’>
<name>dpdk-vpx1</name>
<uuid>aedb844b-f6bc-48e6-a4c6-36577f2d68d6</uuid>
<memory unit=’KiB’>16777216</memory>
<currentMemory unit=’KiB’>16777216</currentMemory>
<memoryBacking>
<hugepages>
<page size=’1048576’ unit=’KiB’/>
</hugepages>
</memoryBacking>
<vcpu placement=’static’>6</vcpu>
<cputune>
<shares>4096</shares>
<vcpupin vcpu=’0’ cpuset=’0’/>
<vcpupin vcpu=’1’ cpuset=’2’/>
<vcpupin vcpu=’2’ cpuset=’4’/>
<vcpupin vcpu=’3’ cpuset=’6’/>
<emulatorpin cpuset=’0,2,4,6’/>
</cputune>
<numatune>
<memory mode=’strict’ nodeset=’0’/>
</numatune>
<resource>
<partition>/machine</partition>
</resource>
<os>
<type arch=’x86_64’ machine=’pc-i440fx-rhel7.0.0’>hvm</type>
<boot dev=’hd’/>
</os>
<features>
<acpi/>
<apic/>
</features>
<cpu mode=’custom’ match=’minimum’ check=’full’>
<model fallback=’allow’>Haswell-noTSX</model>
<vendor>Intel</vendor>
<topology sockets=’1’ cores=’6’ threads=’1’/>
<feature policy=’require’ name=’ss’/>
<feature policy=’require’ name=’pcid’/>
<feature policy=’require’ name=’hypervisor’/>
<feature policy=’require’ name=’arat’/>
<feature policy=’require’ name=’tsc_adjust’/>
<feature policy=’require’ name=’xsaveopt’/>
<feature policy=’require’ name=’pdpe1gb’/>
<numa>
<cell id=’0’ cpus=’0-5’ memory=’16777216’ unit=’KiB’ memAccess=’shared’/>
</numa>
</cpu>
<clock offset=’utc’/>
<on_poweroff>destroy</on_poweroff>
<on_reboot>restart</on_reboot>
<on_crash>destroy</on_crash>
<devices>
<emulator>/usr/libexec/qemu-kvm</emulator>
<disk type=’file’ device=’disk’>
<driver name=’qemu’ type=’qcow2’ cache=’none’/>
<source file=’/home/NSVPX-KVM-12.0-52.18_nc.qcow2’/>
<target dev=’vda’ bus=’virtio’/>
<address type=’pci’ domain=’0x0000’ bus=’0x00’ slot=’0x07’ function=’0x0’/>
</disk>
<controller type=’ide’ index=’0’>
<address type=’pci’ domain=’0x0000’ bus=’0x00’ slot=’0x01’ function=’0x1’/>
</controller>
<controller type=’usb’ index=’0’ model=’piix3-uhci’>
<address type=’pci’ domain=’0x0000’ bus=’0x00’ slot=’0x01’ function=’0x2’/>
</controller>
<controller type=’pci’ index=’0’ model=’pci-root’/>
<interface type=’direct’>
<mac address=’52:54:00:bb:ac:05’/>
<source dev=’enp129s0f0’ mode=’bridge’/>
<model type=’virtio’/>
<address type=’pci’ domain=’0x0000’ bus=’0x00’ slot=’0x03’ function=’0x0’/>
</interface>
<interface type=’vhostuser’>
<mac address=’52:54:00:55:55:56’/>
<source type=’unix’ path=’/var/run/openvswitch/vhost-user1’ mode=’client’/>
<model type=’virtio’/>
<address type=’pci’ domain=’0x0000’ bus=’0x00’ slot=’0x04’ function=’0x0’/>
</interface>
<interface type=’vhostuser’>
<mac address=’52:54:00:2a:32:64’/>
<source type=’unix’ path=’/var/run/openvswitch/vhost-user2’ mode=’client’/>
<model type=’virtio’/>
<address type=’pci’ domain=’0x0000’ bus=’0x00’ slot=’0x05’ function=’0x0’/>
</interface>
<interface type=’vhostuser’>
<mac address=’52:54:00:2a:32:74’/>
<source type=’unix’ path=’/var/run/openvswitch/vhost-user3’ mode=’client’/>
<model type=’virtio’/>
<address type=’pci’ domain=’0x0000’ bus=’0x00’ slot=’0x06’ function=’0x0’/>
</interface>
<interface type=’vhostuser’>
<mac address=’52:54:00:2a:32:84’/>
<source type=’unix’ path=’/var/run/openvswitch/vhost-user4’ mode=’client’/>
<model type=’virtio’/>
<address type=’pci’ domain=’0x0000’ bus=’0x00’ slot=’0x09’ function=’0x0’/>
</interface>
<serial type=’pty’>
<target port=’0’/>
</serial>
<console type=’pty’>
<target type=’serial’ port=’0’/>
</console>
<input type=’mouse’ bus=’ps2’/>
<input type=’keyboard’ bus=’ps2’/>
<graphics type=’vnc’ port=’-1’ autoport=’yes’>
<listen type=’address’/>
</graphics>
<video>
<model type=’cirrus’ vram=’16384’ heads=’1’ primary=’yes’/>
<address type=’pci’ domain=’0x0000’ bus=’0x00’ slot=’0x02’ function=’0x0’/>
</video>
<memballoon model=’virtio’>
<address type=’pci’ domain=’0x0000’ bus=’0x00’ slot=’0x08’ function=’0x0’/>
</memballoon>
</devices>
</domain
Points to note
In the XML file, the hugepage size must be 1 GB, as shown in the sample file.
<memoryBacking>
<hugepages>
<page size=’1048576’ unit=’KiB’/>
</hugepages>
Also, in the sample file vhost-user1 is the vhostuser port bound to ovs-br0.
<interface type=’vhostuser’>
<mac address=’52:54:00:55:55:56’/>
<source type=’unix’ path=’/var/run/openvswitch/vhost-user1’ mode=’client’/>
<model type=’virtio’/>
<address type=’pci’ domain=’0x0000’ bus=’0x00’ slot=’0x04’ function=’0x0’/>
</interface>
To bring up the Citrix ADC VPX instance, start using virsh command.
Share
Share
This Preview product documentation is Cloud Software Group Confidential.
You agree to hold this documentation confidential pursuant to the terms of your Cloud Software Group Beta/Tech Preview Agreement.
The development, release and timing of any features or functionality described in the Preview documentation remains at our sole discretion and are subject to change without notice or consultation.
The documentation is for informational purposes only and is not a commitment, promise or legal obligation to deliver any material, code or functionality and should not be relied upon in making Cloud Software Group product purchase decisions.
If you do not agree, select I DO NOT AGREE to exit.