Factory Reset
-
-
Factory Reset
-
-
-
XenServer 6.5 Upgrade for SD-WAN Standard Edition Appliances
-
SD-WAN Standard Edition Virtual Appliance (VPX) in Hypervisor on HyperV 2012 R2 and 2016
-
Install SD-WAN SE Virtual Appliances (VPX) in Linux-KVM Platform
-
Deploy Citrix SD-WAN Standard Edition Instance on Azure - Release Version 10.2 and above
-
SD-WAN Standard Edition Virtual Appliance (VPX) High Availability support for AWS
-
Deploy a Citrix SD-WAN VPX instance on a Citrix ADC SDX appliance
-
This content has been machine translated dynamically.
Dieser Inhalt ist eine maschinelle Übersetzung, die dynamisch erstellt wurde. (Haftungsausschluss)
Cet article a été traduit automatiquement de manière dynamique. (Clause de non responsabilité)
Este artículo lo ha traducido una máquina de forma dinámica. (Aviso legal)
此内容已经过机器动态翻译。 放弃
このコンテンツは動的に機械翻訳されています。免責事項
이 콘텐츠는 동적으로 기계 번역되었습니다. 책임 부인
Este texto foi traduzido automaticamente. (Aviso legal)
Questo contenuto è stato tradotto dinamicamente con traduzione automatica.(Esclusione di responsabilità))
This article has been machine translated.
Dieser Artikel wurde maschinell übersetzt. (Haftungsausschluss)
Ce article a été traduit automatiquement. (Clause de non responsabilité)
Este artículo ha sido traducido automáticamente. (Aviso legal)
この記事は機械翻訳されています.免責事項
이 기사는 기계 번역되었습니다.책임 부인
Este artigo foi traduzido automaticamente.(Aviso legal)
这篇文章已经过机器翻译.放弃
Questo articolo è stato tradotto automaticamente.(Esclusione di responsabilità))
Translation failed!
Factory Reset
Factory Reset via button pushes
You can restore factory default settings on Citrix SD-WAN 210, 410 and 1100 appliances by performing a reset via button pushes.
To perform factory reset on Citrix SD-WAN 410 appliance:
-
Power OFF the appliance using the power button.
Note
Ensure that the appliance is powered up, but is in OFF state.
-
Using a paper-clip, press and hold the NMI reset button for 5+ seconds or until the power LED starts flashing.
-
While the power LED is flashing, press and release the power button to trigger the factory reset process.
To perform factory reset on Citrix SD-WAN 210 and 1100 appliance:
-
Power OFF the appliance using the power button.
Note
Ensure that the appliance is powered up, but is in OFF state.
-
Using a paper-clip, press and release the NMI button, the power LED starts flashing.
-
Press and release the power button within 3 seconds to trigger the factory reset process.
Tip
- Pressing the NMI reset button even number of times cancels the reset action and results in normal appliance reboot.
- Pressing the reset button odd number of times performs a factory reset.
- Power LED flash indicates that the appliance is being reset.
The appliance restarts and the CLI is displayed. The appliance may reboot 4–5 times as it extracts, copies, and initializes the boot process. At the login prompt, you can start configuring the appliance using CLI or the web management interface.
Factory Reset via Internal USB
You can restore factory default settings on Citrix SD-WAN 210, 410, 1100, 2100, 4100, 5100, and 6100 appliances by performing a reset via the internal USB. These appliances have an internal USB drive that stores the factory default settings.
To reset an appliance via Internal USB:
- Connect a computer to the serial console of the Citrix SD-WAN appliance.
- Reboot the appliance.
- While the appliance boots when you see a cursor moving across the screen, perform the following steps:
- Press and hold the ESC key.
- Press and hold the SHIFT key.
- Press the number 1 key (SHIFT +1 = !) and release all keys.
- Repeat steps a, b, and c until the cursor stops moving.
- Select the internal USB option that is displayed on the boot menu.
Note
The internal USB name may vary for different platforms. There may be similar option with UEFI as well on the boot menu, ignore that and select the one with no UEFI.
Share
Share
In this article
This Preview product documentation is Cloud Software Group Confidential.
You agree to hold this documentation confidential pursuant to the terms of your Cloud Software Group Beta/Tech Preview Agreement.
The development, release and timing of any features or functionality described in the Preview documentation remains at our sole discretion and are subject to change without notice or consultation.
The documentation is for informational purposes only and is not a commitment, promise or legal obligation to deliver any material, code or functionality and should not be relied upon in making Cloud Software Group product purchase decisions.
If you do not agree, select I DO NOT AGREE to exit.